Product Description
- SPECIFICATION:
-
- Optical System: Infinity Optical System.
- Stand: Single Mould Sturdy Aluminum Die-cast Stand (Anti-Rust) Body.
- Viewing Head: Trinocular Head 30 Inclined 360 Rotatable, IPD 48-75mm With Diopter Adjustment.
- Eye Guards: Adjustable Rubber Eye Guards For Comfortable Viewing.
- Eyepieces: Wide Field 10x, F.O.V 22mm With +/-5 Diopteric Adjustment, Antifungal & Anti-reflection Coated.
- Nosepiece: Quintuple Nosepiece Click Stops Mechanism And Rubber Grip.
- Objectives: LWD Plan 4x/0.10, LWD 10x/0.25 PH, LWD 20x/0.50 PH, LWD Plan 40x/0.65 PH.
- Magnification: 40x To 400x.
- Phase Annulus: Fixed And Adjustable Plates For 10X-20X, 40X.
- Mechanical Stage: Graduated Stage Size 160mm X 250mm, X/Y Travel 78mm X 54mm, Scratch-resistant, Double Specimen Holder Clips.
- Focusing: Coaxial Coarse And Fine Focusing. With Fine Adjustment Scale Value 0.002mm
- Condenser: LWD 45mm Condenser With N.A. 0.35. Field Diaphragm, With Pull Out Filter Socket.
- Filter: Blue, Green, Yellow Glass Filter.
- Illumination: 5W LED Light (Up To 100,000 Working hours) with Intensity Controller.
- Power: Universal Power Supply 110v-240v Integrated With Voltage Flux Stabilizer.
- Packaging: Inner Thermocol / Styrofoam Packing And Outer Cardboard Box.
Precision Imaging for Tissue Culture ResearchThe PZQ-105S is specially designed for the observation of living cells and organisms within culture vessels, making it indispensable for researchers in evidence-based biological studies. Its plan achromatic objectives and anti-fungal lenses yield clear, distortion-free images, while integrated digital imaging ensures seamless data documentation. The backward quintuple nosepiece and universal mechanical stage enhance versatility for diverse experimental setups.
Robust Construction for Challenging Lab EnvironmentsCrafted with a sturdy die-cast metal frame and anti-rust finish, this microscope is suitable for humid, dust-free laboratories. Built to support both routine and advanced research, it maintains peak performance even in demanding environmental conditions. The ergonomic design, including trinocular head with adjustable interpupillary distance, prioritizes comfort during extended observation sessions.
Seamless Digital Integration and WorkflowWith an integrated sensor, USB/HDMI connectivity, and compatibility with C-mount digital cameras, the PZQ-105S offers instant image and video capture in various formats. Live streaming and still captures at full HD resolution make data sharing and archiving efficient. The intuitive controls-coaxial coarse and fine focus, adjustable LED illumination-streamline routine lab processes and enhance productivity.
FAQ's of PZQ-105S Advance Inverted Tissue Culture Microscope:
Q: How do I capture and export images or videos from the PZQ-105S microscope?
A: Images and videos can be easily captured using the integrated digital imaging sensor, supporting resolutions up to 1920 x 1080 pixels and live frame rates up to 30 fps. You can export files directly via the USB or HDMI ports, and save them in JPEG, PNG, or BMP formats for further analysis or sharing.
Q: What makes this microscope suitable for tissue culture laboratories?
A: The PZQ-105S is specifically crafted for tissue culture observation. Its inverted design allows easy visualization of living cells in culture vessels. The anti-fungal, plan achromatic optics and transparent or frosted glass stage plates enhance long-term accuracy and prevent sample contamination, making it ideal for use in humid, dust-free lab environments.
Q: When should the transparent versus frosted stage plate be used?
A: The transparent stage plate is ideal for observing specimens that require maximum transmitted light, providing clear views for typical tissue culture work. The frosted plate diffuses light to reduce glare, making it preferable for high-contrast or sensitive samples. The ability to switch between both facilitates optimal imaging conditions for a wide variety of specimens.
Q: Where can the PZQ-105S microscope be operated effectively?
A: This microscope is designed for operation in humid, dust-free environments typical of advanced research and tissue culture laboratories. Its robust anti-rust frame ensures longevity and stable performance even in challenging lab conditions, making it a reliable choice for research institutions, hospitals, and biological manufacturing facilities.
Q: What is the process for adjusting focus and magnification during use?
A: Users can switch between 40x, 100x, and 400x magnifications by rotating the backward quintuple revolving nosepiece. Focusing is achieved via coaxial coarse and fine adjustment knobs, with coarse adjustment providing 30 mm of travel and fine adjustment enabling precise 0.002 mm graduations. This system ensures crisp, detailed visualization at all magnification levels.
Q: How does digital imaging benefit routine and research tissue culture work?
A: Digital imaging enables quick documentation and analysis of microscopic specimens. With instant high-definition photo and video capture, data can be archived, shared, or analyzed remotely. This streamlines workflow, facilitates collaborations, and enhances overall research accuracy and reproducibility.